The
PELLU Metals Removal Process
removes all heavy metals from waste water, is not pH sensitive, and is highly
efficient even in the presence of interfering agents (EDTA,
ammonia, sulfates, phosphates, etc.). It encompasses
the concepts of pollution prevention, waste minimization, and
resource recycling.
|
How to use the PELLU CWT80 Waste Treatment Process:
-
Wastewater is pumped from a holding tank or directly from
the process line into the 80 gallon batch reaction tank.
-
The
semi-automated system is initiated by the operator when
prompted by the display.
-
When the
tank is full, the pH controller begins injecting the PELLU
chemical into the reaction tank until the pH reaches the
desired setpoint depending upon the metals to be removed.
-
Once the
pH value is met, the selected polymer for the application is
automatically injected into the tank in the correct
proportion. The mixer speed increases for a preset time, and
then automatically slows to ensure settling.
-
The
solids are then collected in a dual filter bag system that
retain the solid floc until final disposal.
-
Treated
water collects in the bottom of the unit and is
automatically transferred by the sump pump to the sewer or
to a holding tank for final discharge.
|